Skip to content

MSAT yield investigation run

RUN-2026-1042Awaiting human authorization

Deterministic trace of what the MSAT Yield Sentry read, computed and proposed for INV-104. Click a step to inspect it; expand the raw log to see exact tool calls.

Agent: MSAT Yield Sentry · policy v4Owner: Alex RiveraTriggered by ALM-UP-204 · 2026-10-19 08:26 UTCRead-only · writeback LOCKED
Frame AGENT-02

Human gate: the agent has stopped and cannot proceed on its own

Proposal RCP-AB014-V4.patch.02 needs signatures from the MSAT Lead (Alex Rivera) and QA Reviewer (Priya Natarajan). Until both sign, nothing is applied to the recipe, equipment or batch record.

Steps completed

5/5

Checkpoint after step 5

Telemetry points

Observation

24,190

42 imputed, excluded

Total duration

6m 41s

08:26:04–08:32:45 UTC

Execution status

AWAITING_HUMAN_AUTHORIZATION

  1. Inputs

    • Workspace INV-104 scope: BR-UP-01, PM-204
    • Batches MES-26071, MES-26072, MES-26073
    • Window T+0–280h

    Outputs

    • Observation24,190 telemetry points across 7 tags (read-only)
    • Observation3 eBR phase records, 2 LIMS result sets, 4 Maximo records
    • UnknownSAP ERP not connected — material cost context unavailable
  2. Inputs

    • 24,190 raw points
    • Inoculation timestamps from eBR (T+0)

    Outputs

    • CalculatedAll batches aligned on elapsed time from inoculation; timezone UTC confirmed
    • Imputed42-min historian gap at T+182.0–182.7h backfilled with Kalman (RTS) estimate — 42 points flagged
    • CalculatedImputed points excluded from every downstream statistic
  3. Inputs

    • Alarm ALM-UP-204 at T+264.4h
    • PM-204 maintenance history (30 days)

    Outputs

    • ObservationWO-8819 raised occlusion clamp torque 0.42 → 0.55 N·m at T-48h; dynamic slip verification not performed
    • ObservationCAL-3310 static flow calibration passed; dynamic slip test deferred
    • ObservationSOP-UP-014 Rev 7 §7.2 requires dynamic slip verification after occlusion adjustment
  4. Inputs

    • Aligned telemetry (non-imputed)
    • CMMS correlation notes
    • Feed media CoA FM-2207
    • DO probes A/B

    Outputs

    • HypothesisA · Over-occlusion / tubing fatigue after WO-8819 — supported by pressure rise and droop timing; not established
    • ContradictedB · Feed media lot FM-2207 out of spec — contradicted: osmolality and glucose within spec
    • ContradictedC · DO probe drift — contradicted: probes A/B agree within 0.6%
  5. Inputs

    • Hypothesis A (supported, not established)
    • SOP-UP-014 §7.2
    • Recipe RCP-AB014-V4

    Outputs

    • ProposalProposal RCP-AB014-V4.patch.02: closed-loop feed cascade on gravimetric delivery
    • ProposalProposed maintenance: replace tubing TS-24-0931 and perform dynamic slip verification per §7.2
    • UnknownRouted to REV-01; requires MSAT Lead and QA Reviewer signatures. Not approved, not executed.