MSAT yield investigation run
RUN-2026-1042Awaiting human authorizationDeterministic trace of what the MSAT Yield Sentry read, computed and proposed for INV-104. Click a step to inspect it; expand the raw log to see exact tool calls.
Agent: MSAT Yield Sentry · policy v4Owner: Alex RiveraTriggered by ALM-UP-204 · 2026-10-19 08:26 UTCRead-only · writeback LOCKED
Human gate: the agent has stopped and cannot proceed on its own
Proposal RCP-AB014-V4.patch.02 needs signatures from the MSAT Lead (Alex Rivera) and QA Reviewer (Priya Natarajan). Until both sign, nothing is applied to the recipe, equipment or batch record.
Steps completed
5/5
Checkpoint after step 5
Telemetry points
Observation24,190
42 imputed, excluded
Total duration
6m 41s
08:26:04–08:32:45 UTC
Execution status
AWAITING_HUMAN_AUTHORIZATION
Inputs
- Workspace INV-104 scope: BR-UP-01, PM-204
- Batches MES-26071, MES-26072, MES-26073
- Window T+0–280h
Outputs
- Observation24,190 telemetry points across 7 tags (read-only)
- Observation3 eBR phase records, 2 LIMS result sets, 4 Maximo records
- UnknownSAP ERP not connected — material cost context unavailable
Inputs
- 24,190 raw points
- Inoculation timestamps from eBR (T+0)
Outputs
- CalculatedAll batches aligned on elapsed time from inoculation; timezone UTC confirmed
- Imputed42-min historian gap at T+182.0–182.7h backfilled with Kalman (RTS) estimate — 42 points flagged
- CalculatedImputed points excluded from every downstream statistic
Inputs
- Alarm ALM-UP-204 at T+264.4h
- PM-204 maintenance history (30 days)
Outputs
- ObservationWO-8819 raised occlusion clamp torque 0.42 → 0.55 N·m at T-48h; dynamic slip verification not performed
- ObservationCAL-3310 static flow calibration passed; dynamic slip test deferred
- ObservationSOP-UP-014 Rev 7 §7.2 requires dynamic slip verification after occlusion adjustment
Inputs
- Aligned telemetry (non-imputed)
- CMMS correlation notes
- Feed media CoA FM-2207
- DO probes A/B
Outputs
- HypothesisA · Over-occlusion / tubing fatigue after WO-8819 — supported by pressure rise and droop timing; not established
- ContradictedB · Feed media lot FM-2207 out of spec — contradicted: osmolality and glucose within spec
- ContradictedC · DO probe drift — contradicted: probes A/B agree within 0.6%
Inputs
- Hypothesis A (supported, not established)
- SOP-UP-014 §7.2
- Recipe RCP-AB014-V4
Outputs
- ProposalProposal RCP-AB014-V4.patch.02: closed-loop feed cascade on gravimetric delivery
- ProposalProposed maintenance: replace tubing TS-24-0931 and perform dynamic slip verification per §7.2
- UnknownRouted to REV-01; requires MSAT Lead and QA Reviewer signatures. Not approved, not executed.
Your companion